A broken wire in a gondola wire rope is a warning, but the correct response depends on its location, the rope’s construction, the number and distribution of breaks, and the applicable discard criteria. Do not judge the rope by one visible section or assume it is safe because the overall diameter looks unchanged. If damage is found and its significance cannot be established immediately, keep the equipment out of service until an authorized person has assessed it.
A useful inspection follows the rope through the entire working path, including areas at the hoist, suspension points and end terminations. It also records enough detail to distinguish a new isolated break from a growing pattern of fatigue or localized damage.
Review the gondola and hoist manufacturer’s instructions before starting. Identify the specified rope type, the inspection method, the relevant discard criteria and any requirements for a competent person. Suspended access equipment carries people, so a general rule for another type of lifting rope must not be substituted for the requirements that apply to the particular system.
Take the platform out of service and secure it against unintended movement. Follow the equipment’s isolation and access procedures, including fall protection where required. Do not place hands near a running hoist, sheave or pinch point. If the rope must be moved to expose a section, use the manufacturer’s inspection procedure and keep personnel clear of moving parts.
Gather the rope identification and previous inspection records, a suitable light, a clean cloth, a measuring tool for diameter checks and a way to mark and record locations. Wear suitable gloves when handling rope: broken wire ends can puncture skin. Remove loose dirt only as permitted by the manufacturer; aggressive cleaning can damage the rope or remove necessary lubricant.
Inspect every accessible length of the working rope and any independent safety rope, paying particular attention to areas exposed to repeated bending, contact or moisture. The rope may look sound between these points while damage is concentrated in a short section.

Use the rope’s path to organize the inspection rather than looking only at the portions visible from the platform. Follow the manufacturer’s procedure for accessing concealed or difficult-to-reach sections. A portion that cannot be inspected should not be recorded as having passed.
Look closely for protruding wire ends, sharp points, gaps in a strand and small bright or dark breaks on the rope surface. A wire may break at the outer crown of a strand, where it contacts a surface, or in a valley between strands. Valley breaks are easy to overlook and may be significant under the applicable discard criteria.
Inspect around the rope’s circumference as access and the manufacturer’s instructions allow. Use a light from different angles to reveal wire ends hidden by grease or shadow. A gloved hand may help detect irregularities where permitted, but touch alone is not a reliable inspection method and should not replace a visual examination.
When a break is found, establish its exact location and inspect the surrounding length carefully. Count broken individual wires, not strands, using the length and counting method specified by the applicable instructions. A rope lay is the distance along the rope in which a strand makes one complete turn around it; some discard criteria use a measured length of rope lay. Do not estimate the count from memory or transfer a numerical limit from a different rope or machine.
Record whether breaks are scattered or concentrated, whether they occur in one strand or several, and whether they are at a termination or in a valley. Local clustering may lead to a different decision from the same total number spread over a longer length. Do not bend wire ends back into place or cut them off to make the rope easier to handle: that can conceal the evidence needed for assessment.
Broken wires are only one part of the inspection. A rope can be unsuitable for continued use even when few or no broken wires are visible. Check for the following conditions alongside the wire count:
Do not force strands apart or attempt an internal examination unless the prescribed procedure and the inspector’s qualifications allow it. For coated rope, the coating can hide the wires beneath it. A clean-looking coating is not proof that the rope is intact; follow the equipment manufacturer’s instructions for inspection and replacement.
Remove the equipment from service when the rope meets a discard condition in the applicable manufacturer instructions or governing requirements. Also isolate it when damage is suspected but cannot be assessed reliably. A competent person should evaluate the findings against the criteria for that specific rope and suspended access system before any return to service.
Do not rely on a single broken-wire count if there is also corrosion, deformation, termination damage or evidence of a hoist fault. Some conditions may require removal independently of the number of visible breaks. Likewise, replacing the rope without investigating a damaged guide, sheave or traction mechanism can leave the cause in place.
A practical inspection record should identify the equipment and rope, inspection date, location of each defect, measured length used for the count, number and distribution of breaks, other damage observed, and the decision made. Photographs with a scale and a clear location reference help later inspections compare the same section. Record any inaccessible areas and the action taken to address them.
Replacement is an equipment compatibility decision, not simply a matter of matching diameter. The specified construction, strength, material, lay, surface condition, termination and compatibility with the hoist and safety devices all matter. Use the rope specified or approved by the gondola manufacturer and follow its installation and commissioning instructions.
For context, Shandong Faster supplies 7x7 Stainless Steel Wire Rope 0.5-6mm use For clothesline and fence for applications including outdoor fixation and control cables. Its material and diameter options do not, by themselves, establish suitability for a personnel-carrying gondola. A replacement must match the suspended access system’s approved specification before it is installed.
After installation, document the replacement and inspect the associated rope path and fittings before returning the equipment to service. Keep the rejected rope clearly identified and segregated so it cannot be put back into use.